POLY-GPG

General Purpose Resin Mortar

Chemical anchor for use in concrete and masonry. Specially formulated for light or medium duty fixing into hollow or solid base materials. It can be used indoor (COV A+) and can be thrown with standard waste

CE-märkt
Tekniskt avtal
Kan anvämdas i fuktig miljö
Indoor
Outdoor
Kantavstånd och lågt internt avstånd

Produktinformation

Bilder

Egenskaper

Material

  • Styrene free polyester
  • Use with Simpson Strong-Tie threaded rod (LMAS) : galvanised steel and stainless A4-70

Benefits

  • Peeler cardridge: quick and simple use
  • Hazardless components, styren free and odorless,
  • Can be stock with non-flammable goods,
  • The cardridge can be thrown (used or not) with standard goods
  • Exists in several colors: beige, grey and white.

Applikationer

Suitable on

  • Brick.
  • Hollow or solid masonry..
  • Cellular concrete

When to use

  • Blinds
  • Hinges
  • Air conditioners
  • Satellite Dishes
  • Boilers

Teknisk data

Références

Table "Références" cannot be displayed : no references available.

Design resistance – Tension – NRd [kN] – Carbon steel 5.8

Art. nr. Design resistance – NRd – Carbon steel 5.8 [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + LMAS M86.36.36.36.39.49.49.49.4
POLY-GPG + LMAS M109.89.89.89.814.714.714.714.7
POLY-GPG + LMAS M1213.113.113.113.119.619.619.619.6
POLY-GPG + LMAS M1619.919.919.919.929.929.929.929.9
POLY-GPG + LMAS M2028.728.728.728.743.143.143.143.1
POLY-GPG + LMAS M2437.937.937.937.956.856.856.856.8

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Tension – NRd [kN] – Stainless steel A4-70

Art. nr. Design resistance – NRd – Stainless steel A4-70 [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + LMAS M86.36.36.36.39.49.49.49.4
POLY-GPG + LMAS M109.89.89.89.814.714.714.714.7
POLY-GPG + LMAS M1213.113.113.113.119.619.619.619.6
POLY-GPG + LMAS M1619.919.919.919.929.929.929.929.9
POLY-GPG + LMAS M2028.728.728.728.743.143.143.143.1
POLY-GPG + LMAS M2437.937.937.937.956.856.856.856.8

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Shear – VRd [kN] – Carbon steel 5.8

Art. nr. Design resistance – VRd – Carbon steel 5.8 [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + LMAS M87.27.27.27.27.27.27.27.2
POLY-GPG + LMAS M101212121212121212
POLY-GPG + LMAS M1216.816.816.816.816.816.816.816.8
POLY-GPG + LMAS M1631.231.231.231.231.231.231.231.2
POLY-GPG + LMAS M2048.848.848.848.848.848.848.848.8
POLY-GPG + LMAS M2470.470.470.470.470.470.470.470.4

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Shear – VRd [kN] – Stainless steel A4-70

Art. nr. Design resistance – VRd – Stainless steel A4-70 [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + LMAS M88.38.38.38.38.38.38.38.3
POLY-GPG + LMAS M1012.812.812.812.812.812.812.812.8
POLY-GPG + LMAS M1219.219.219.219.219.219.219.219.2
POLY-GPG + LMAS M1635.335.335.335.335.335.335.335.3
POLY-GPG + LMAS M2055.155.155.155.155.155.155.155.1
POLY-GPG + LMAS M2479.579.579.579.579.579.579.579.5

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Bending moment – MRd [Nm] – Concrete

Art. nr. Design resistance – Bending moment – MRd  - Concrete [Nm]
Carbon steel 5.8 Stainless steel A4-70
POLY-GPG + LMAS M815.216.7
POLY-GPG + LMAS M1029.633.3
POLY-GPG + LMAS M125260.9
POLY-GPG + LMAS M16132.8148.7
POLY-GPG + LMAS M20259.2291
POLY-GPG + LMAS M24448502.6

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – hef = 80 mm (≤ M8) or 85 mm (≥ M10) – Carbon steel ≥ 4.6 / Stainless steel ≥ A2-70

Art. nr. Design resistance – Carbon steel ≥ 4.6 / stainless steel ≥ A2-70
hef = 80 mm (≤ M8) or 85 mm ( ≥ M10)
Tension - NRd [kN] Shear - VRd [kN]
Solid Clay Masonry Hollow Masonry Solid Clay Masonry Hollow Masonry
POLY-GPG + LMAS M81.60.30.80.6
POLY-GPG + LMAS M1020.62.40.6
POLY-GPG + LMAS M1220.62.40.6
POLY-GPG + LMAS M16----
POLY-GPG + LMAS M20----
POLY-GPG + LMAS M24----

Masonry :

 

 Compressive strength fb [N/mm²]Bulk density ρ [kg/m3]
Solid clay masonry≥ 18≥ 1600
Hollow masonry≥ 6≥ 900

 

1. The design resistances have been calculated using the partial safety factors for resistances stated in ETA-approval(s).
2. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4.
3. For combined tension and shear loads or anchor groups and/or in case of edge influence, a calculation acc. TR 054, design method A shall be performed. For details see ETA - assessment(s)
4. Temperature range: -40°C/+40°C (Tmlp = +24°C)
5. Coefficiant factor β for in situ tests acc. ETAG 029 see ETA-19/XXXX; Annex C2
6. Displacements under service load see ETA-19/0420; Annex C2 & C3

Design resistance – Bending moment – MRd [Nm] – Masonry

Art. nr. Design resistance – Bending moment – MRd - Masonry [Nm]
Carbon steel 5.8 Carbon steel 8.8 Stainless steel ≥ A2-70
POLY-GPG + LMAS M66.49.67.1
POLY-GPG + LMAS M815.22416.7
POLY-GPG + LMAS M1029.64833.3
POLY-GPG + LMAS M1252.88459
POLY-GPG + LMAS M16---
POLY-GPG + LMAS M20---
POLY-GPG + LMAS M24---
POLY-GPG + Ø8---
POLY-GPG + Ø10---
POLY-GPG + Ø12---
POLY-GPG + Ø16---
POLY-GPG + Ø20---
POLY-GPG + Ø25---
POLYGPG300BG-SE---

Masonry :

 

 Compressive strength fb [N/mm²]Bulk density ρ [kg/m3]
Solid clay masonry≥ 18≥ 1600
Hollow masonry≥ 6≥ 900

 

1. The design resistances have been calculated using the partial safety factors for resistances stated in ETA-approval(s).
2. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4.
3. For combined tension and shear loads or anchor groups and/or in case of edge influence, a calculation acc. TR 054, design method A shall be performed. For details see ETA - assessment(s)
4. Temperature range: -40°C/+40°C (Tmlp = +24°C)
5. Coefficiant factor β for in situ tests acc. ETAG 029 see ETA-19/XXXX; Annex C2
6. Displacements under service load see ETA-19/0420; Annex C2 & C3

 

Design resistance – Tension – NRd [kN] – Rebar

Art. nr. Design resistance – NRd – Rebar [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + Ø84.94.94.94.97.47.47.47.4
POLY-GPG + Ø107.77.78.48.411.511.512.712.7
POLY-GPG + Ø1211.112.212.213.316.618.218.219.9
POLY-GPG + Ø1615.316.816.818.42325.325.327.6
POLY-GPG + Ø2023.926.326.328.735.939.539.543.1
POLY-GPG + Ø2537.441.144.948.653.859.264.670

Design resistance – Shear – VRd [kN] – Rebar

Art. nr. Design resistance – VRd  – Rebar [kN]
Non-cracked concrete
hef = 8d hef = 12d
C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60
POLY-GPG + Ø899999999
POLY-GPG + Ø1014.214.214.214.214.214.214.214.2
POLY-GPG + Ø1220.320.320.320.320.320.320.320.3
POLY-GPG + Ø1636.236.236.236.236.236.236.236.2
POLY-GPG + Ø2056.556.556.556.556.556.556.556.5
POLY-GPG + Ø2588.488.488.488.488.488.488.488.4

Design resistance – Bending moment – MRd [Nm] – Rebar

Art. nr. Design resistance – Bending moment – MRd – Rebar [Nm]
POLY-GPG + Ø821.6
POLY-GPG + Ø1042.3
POLY-GPG + Ø1273.5
POLY-GPG + Ø16173.7
POLY-GPG + Ø20339.1
POLY-GPG + Ø25662.7

Montage

Montage

Curing Schedule

Temperature of the anchorage base

Tbase material

Working time (Gel time)

tgel

Curing time (in dry concrete)

tcure, dry

Curing time (in wet concrete)

tcure, wet

0°C ≤ Tbase material < +10°C20 min90 min3:00 h
+10°C ≤ Tbase material < +20°C9 min60 min2:00 h
+20°C ≤ Tbase material < +30°C5 min30 min1:00 h
+30°C ≤ Tbase material ≤ 40°C 3 min20 min40 min

• Manual Air Cleaning (MAC) for all drill hole diameters d0 ≤ 24 mm and drill holl depth h0 ≤ 10d : 
          4x blowing (hand pump)
          4x brushing
          4x blowing (Hand pump)

• Compressed Air Cleaning (CAC) for all drill hole diameters d0 and drill hole depths :
          2x blowing (min. 6 bar - oil free compressed air)
          2x brushing
          2x blowing (min. 6 bar - oil free compressed air)

• Cartridge temperature (Bond material) : ≥ +20°C

 

Installation parameters – Concrete

Art. nr. Installation parameters - Concrete
Ø drilling [d0] [mm] Max. fixture hole Ø [df] [mm] Drilling depth (8d) [h0=hef=8d] [mm] Drilling depth (12d) [h0=hef=12d] [mm] Wrench size [SW] Installation torque [Tinst] [Nm]
POLY-GPG + LMAS M810964961310
POLY-GPG + LMAS M101212801201712
POLY-GPG + LMAS M121414961441920
POLY-GPG + LMAS M1618181281962440
POLY-GPG + LMAS M2024221602403070
POLY-GPG + LMAS M2428261922883690

Spacing, edge distances and member thickness – Concrete

Art. nr. Spacing, edge distance and member thickness - Concrete
Effective embedment depth (8d) [hef,8d] [mm] Characteristic spacing for hef,8d [Scr,N] [mm] Characteristic edge distance for hef,8d [ccr,N] [mm] Min. member thickness for hef,8d [hmin] [mm] Effective embedment depth (12d) [hef,12d] [mm] Characteristic spacing for hef,12d [Scr,N] [mm] Characteristic edge distance for hef,12d [ccr,N] [mm] Min. member thickness for hef,12d [hmin] [mm] Min. spacing [Smin] [mm] Min. edge distance [Cmin] [mm]
POLY-GPG + LMAS M86419296100962881441264040
POLY-GPG + LMAS M10802401201101203601801505050
POLY-GPG + LMAS M12962881441261444322161746060
POLY-GPG + LMAS M161283841921581965882942268080
POLY-GPG + LMAS M20160480240190240720360270100100
POLY-GPG + LMAS M24192576288222288864432318120120

Installation parameters – Masonry – Solid clay masonry

Art. nr. Installation parameters - Solid clay masonry
Ø drilling [d0] [mm] Max. fixture hole Ø [df] [mm] Drilling depth [h1] [mm] Embedment depth [hef] [mm] Installation torque [Tinst] [Nm]
POLY-GPG + LMAS M68785801
POLY-GPG + LMAS M810985801
POLY-GPG + LMAS M10121290851
POLY-GPG + LMAS M12141490851

Installation parameters – Masonry – Hollow masonry

Art. nr. Installation parameters - Hollow masonry
Ø drilling [d0] [mm] Max. fixture hole Ø [df] [mm] Drilling depth [h1] [mm] Embedment depth [hef] [mm] Installation torque [Tinst] [Nm]
POLY-GPG + LMAS M612785802
POLY-GPG + LMAS M812985802
POLY-GPG + LMAS M10161290852
POLY-GPG + LMAS M12161490852

Spacing, edge distances and member thickness – Masonry – Solid clay masonry

Art. nr. Spacing, edge distance and member thickness - Solid clay masonry
Min. spacing [Smin] [mm] Min. edge distance [Cmin] [mm]
scr,N = smin [mm] scr,N ∥ = smin ∥ [mm] scr,NT = sminT [mm] ccr,N = cmin [mm]
POLY-GPG + LMAS M6240--120
POLY-GPG + LMAS M8240--120
POLY-GPG + LMAS M10255--127.5
POLY-GPG + LMAS M12255--127.5

Spacing, edge distances and member thickness – Masonry – Hollow masonry

Art. nr. Spacing, edge distance and member thickness - Hollow masonry
Min. spacing [Smin] [mm] Min. edge distance [Cmin] [mm]
scr,N = smin [mm] scr,N ∥ = smin ∥ [mm] scr,N T = smin T [mm] ccr,N = cmin [mm]
POLY-GPG + LMAS M6-250120100
POLY-GPG + LMAS M8-250120100
POLY-GPG + LMAS M10-250120100
POLY-GPG + LMAS M12-250120100

Installation parameters – Rebar

Art. nr. Installation parameters – Rebar
Ø drilling [d0] [mm] Drilling depth (8d) [h0=hef=8d] [mm] Drilling depth (12d) [h0=hef=12d] [mm]
POLY-GPG + Ø8126496
POLY-GPG + Ø101480120
POLY-GPG + Ø121696144
POLY-GPG + Ø1620128192
POLY-GPG + Ø2025160240
POLY-GPG + Ø2532200288

Spacing, edge distances and member thickness – Rebar

Art. nr. Spacing, edge distance and member thickness – Rebar
Effective embedment depth (8d) [hef,8d] [mm] Characteristic spacing for hef,8d [Scr,N] [mm] Characteristic edge distance for hef,8d [ccr,N] [mm] Min. member thickness for hef,8d [hmin] [mm] Effective embedment depth (12d) [hef,12d] [mm] Characteristic spacing for hef,12d [Scr,N] [mm] Characteristic edge distance for hef,12d [ccr,N] [mm] Min. member thickness for hef,12d [hmin] [mm] Min. spacing [Smin] [mm] Min. edge distance [Cmin] [mm]
POLY-GPG + Ø86419296100962881441264040
POLY-GPG + Ø10802401201101203601801505050
POLY-GPG + Ø12962881441261444322161746060
POLY-GPG + Ø161283841921681925762882328080
POLY-GPG + Ø20160480240210240720360290100100
POLY-GPG + Ø25200600300264288864432352120120

Certifiering

European Technical Assessment (ETA)

eta-19-0626.pdf (1.4 MB)
eta-19-0627.pdf (1.16 MB)

ZIP-paket

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie Sverige

Simpson Strong-Tie AB

Bruksvägen 2
59375 Gunnebo
Sverige